blog迁移至
:http://www.micmiu.com
keepalived是一个类似于layer3, 4,
5 交换机制的软件,也就是我们平时说的第3层、第4层和第5层交换。Keepalived的作用是检测web服务器的状态,如果有一台web服务器死机,或工作出现故障,Keepalived将检测到,并将有故障的web服务器从系统中剔除,当web服务器工作正常后Keepalived自动将web服务器加入到服务器群中,这些工作全部自动完成,不需要人工干涉,需要人工做的只是修复故障的web服务器。
官网地址:http://www.keepalived.org/
截止目前最新版本1.2.2 附件提供下载:keepalived-1.2.2.tar.gz
keepalived 中文权威指南:KEEPALIVED权威指南_中文_.pdf
本文目录:
-
[一]、实验环境介绍
-
[二]、服务器层的双机热备(比如服务器宕机、keepalived宕、网络不通)
-
[三]、应用层(web)的双机热备(比如web应用端口不通、
nginx进程被意外kill
)
[一]、实验环境介绍
1.1、软件信息:
- S-A 192.168.8.183 centos5 keepalived nginx
- S-B 192.168.8.150 centos5 keepalived nginx
- VirtualIP (虚拟IP):192.168.8.191
1.2、keepalived 标准的安装步骤:
# tar -zxvf keepalived-1.2.2.tar.gz
# cd keepalived-1.2.2
# ./configure
# make
# make install
# mkdir /etc/keepalived/
# cp /usr/local/etc/keepalived/keepalived.conf /etc/keepalived/keepalived.conf
1.3、nginx的安装和keepalived类似
不熟悉的可参考:nginx安装及负载均衡配置
(http://sjsky.iteye.com/blog/1156195)
修改nginx.conf 中监听端口80->8088:
listen 8088;
server_name localhost;
修改/usr/local/nginx/html/index.html的内容:
192.168.8.183
<html>
<head>
<title>Welcome to nginx!</title>
</head>
<body bgcolor="white" text="black">
<center><h1>Welcome to nginx! 192.168.8.183</h1></center>
</body>
</html>
192.168.8.150:
<html>
<head>
<title>Welcome to nginx!</title>
</head>
<body bgcolor="white" text="black">
<center><h1>Welcome to nginx! 192.168.8.150</h1></center>
</body>
</html>
两台server(S-A,S-B)都需要安装这两款软件。
[二]、服务器层的双机热备(比如服务器宕机、keepalived宕了)
2.1、测试要求:
主机宕机、keepalived宕了、网络不通时,备机能自动接管,不影响VIP:192.168.8.191的访问
2.2、Master(S-A 192.168.8.181)配置文件/etc/keepalived/keepalived.conf:
! Configuration File for keepalived
global_defs {
notification_email {
#admin@michael-demo.com
}
#notification_email_from admin@michael-demo.com
#smtp_server 127.0.0.1
#smtp_connect_timeout 30
router_id LVS_DEVEL
}
vrrp_instance VI_1 {
state MASTER
interface eth0
virtual_router_id 51
priority 100
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
192.168.8.191
}
}
2.3、Backup(S-B 192.168.8.150)配置信息/etc/keepalived/keepalived.conf:
! Configuration File for keepalived
global_defs {
notification_email {
#admin@michael-demo.com
}
#notification_email_from admin@michael-demo.com
#smtp_server 127.0.0.1
#smtp_connect_timeout 30
router_id LVS_DEVEL
}
vrrp_instance VI_1 {
state BACKUP
interface eth0
virtual_router_id 51
priority 99
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
192.168.8.191
}
}
Tips:
-
state 参数值:主的是MASTER、备用的是BACKUP
-
priority 参数值: MASTER > BACKUP
-
virtual_router_id: 参数值要一样
2.4、测试:
两台测试机S-A、S-B均启动keepalived和nginx
2.4.1、验证nginx启动正常:
访问 master : http://192.168.8.183:8088/
访问 backup: http://192.168.8.150:8088/
2.4.2、查看keepalived的日志信息如下:
master :192.168.8.183
backup:192.168.8.150
2.4.3、浏览器打开虚拟ip访问:http://192.168.8.191:8088/
2.4.4、kill 192.168.8.181(master) 的keepalived进程,日志信息如下:
master :192.168.8.183
backup:192.168.8.150
2.4.5、浏览器打开虚拟ip访问:http://192.168.8.191:8088/
2.4.6、再次启动192.168.8.181的keepalived进程,192.168.8.181会自动接管成为master,192.168.8.150自动转为backup,从测试结果看,备机能成功接管,已经实现了热备。
Tips:
如果我们停掉master上的nginx进程,你会发现此时应用访问就失败了,很显然这不是我们希望看到的结果,那如何实现web应用的热备呢,在下一节中我们将详细讲述。
[三]、应用层(web)的双机热备(比如nginx进程被意外kill、web端口不通)
3.1.主要是利用keepalived的track_script检测脚本的原理实现的。
3.2.配置文件的修改
3.2.1、Master(S-A 192.168.8.181)配置文件/etc/keepalived/keepalived.conf:
/etc/keepalived/keepalived.conf
! Configuration File for keepalived
global_defs {
notification_email {
#admin@michael-demo.com
}
#notification_email_from admin@michael-demo.com
#smtp_server 127.0.0.1
#smtp_connect_timeout 30
router_id LVS_DEVEL
}
vrrp_script chk_http_port {
script "</dev/tcp/127.0.0.1/8088"
interval 1
weight -2
}
vrrp_instance VI_1 {
state MASTER
interface eth0
virtual_router_id 51
priority 100
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
192.168.8.191
}
track_script {
chk_http_port
}
}
3.2.2、Backup(S-B 192.168.8.150)配置文件/etc/keepalived/keepalived.conf:
/etc/keepalived/keepalived.conf
! Configuration File for keepalived
global_defs {
notification_email {
#admin@michael-demo.com
}
#notification_email_from admin@michael-demo.com
#smtp_server 127.0.0.1
#smtp_connect_timeout 30
router_id LVS_DEVEL
}
vrrp_script chk_http_port {
script "</dev/tcp/127.0.0.1/8088"
interval 1
weight -2
}
vrrp_instance VI_1 {
state MASTER
interface eth0
virtual_router_id 51
priority 99
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
192.168.8.191
}
track_script {
chk_http_port
}
}
3.2.3、注意点(非常重要)
1)、为什么主备的参数state都是MASTER,对的你没有看错确实要都设置成一样的,不然并不能实现我们想要的VIP漂浮的效果,我测试很久才发现的.state都设置成MASTER后,会根据priority的值大小竞争来决定谁是真正的MASTER,脚本检测也是在失败的时候会把权重减去相应的值,比如原来master(181)的priority=100,如果脚本检测到端口8088无法连接,就会priority-2=98,< S-B(150)的priority(99),此时
S-B(150)
将竞争成为master,这样就实现了web应用的热备。
2)、配置文件格式一定要注意,比如:track_script {,在“track_script”和“{”之间一定要加空格
,本来测试时少了个空格,一直无法运行检测脚本,调试了很久,非常郁闷
3.3、测试过程和上面的过程基本一致。
本文连接:http://sjsky.iteye.com/blog/1156403
转载请注明来自:Michael's blog @ http://sjsky.iteye.com
----------------------------- 分 ------------------------------ 隔 ------------------------------ 线 ------------------------------
- 大小: 35.8 KB
- 大小: 36 KB
- 大小: 38.1 KB
- 大小: 25.9 KB
- 大小: 36.6 KB
- 大小: 6.2 KB
- 大小: 4.1 KB
- 大小: 35.7 KB
分享到:
相关推荐
Nginx+keepalived双机热备(主从模式)是一种常见的负载均衡技术,用于实现高可用环境和故障转移。该技术通过将Nginx与keepalived结合,实现了前端负载均衡和高可用性。 Nginx是一款流行的开源Web服务器软件,具有...
nginx+keepalived实现双机热备高可用 本文详细介绍了使用nginx和keepalived实现双机热备高可用的技术解决方案。该解决方案旨在解决nginx集群部署时的单点故障问题。通过keepalived软件,实现对nginx服务器的高可用...
本文档介绍了如何构建Keepalived双机热备架构,以便在网络中部署高可用的负载均衡服务。 ### Keepalived双机热备原理 Keepalived通过虚拟路由冗余协议(VRRP)实现双机热备,其核心思想是将两台服务器设定为主备...
【标题】:Linux环境下基于Keepalived的MySQL双机热备实现详解 【描述】:在企业级系统中,数据库往往是性能瓶颈的关键所在。MySQL主从架构虽然能缓解这一问题,但在面临单一主库故障时,系统仍存在风险。本文将...
本文将详细介绍 MYSQL+KEEPALIVED 双机热备方案的实现细节。 MYSQL 主主复制配置 MYSQL 主主复制是 MYSQL+KEEPALIVED 双机热备方案的核心组件。通过配置 MYSQL 主主复制,可以实现两个 MYSQL 节点的实时数据同步,...
标题 "keepalived + redis 实现双机热备" 涉及到的是在IT行业中构建高可用性系统的关键技术。keepalived 和 redis 是两个关键组件,它们一起工作以确保服务的持续运行,即使在主服务器故障时也能无缝切换到备份...
### Nginx负载均衡与Keepalived双机热备配置详解 #### 一、环境配置与准备工作 在介绍具体的配置步骤之前,我们首先需要明确一下本案例中的环境配置: - **负载均衡器**: - **LB主**:192.168.1.1 - **LB从**...
而"linux下免费的双机热备软件"提到的就是Keepalived,它是一个开源的解决方案,提供了高可用性和负载均衡功能。 Keepalived是基于VRRP(Virtual Router Redundancy Protocol,虚拟路由冗余协议)设计的,主要用于...
本片详细记录了Nginx+keepalived双机热备(主从模式)高可用集群方案-完整部署过程,讲解十分到位,可作为线上实操手册。特在此分享,希望能帮助到有用到的朋友。
在IT行业中,双机热备是一种常见的高可用性解决方案,用于确保关键...总的来说,Keepalived通过VRRP协议实现了双机热备,提供了高可用性和负载均衡的能力。通过合理的配置,可以有效地保护关键业务免受单点故障的影响。
在双机linux系统中用于vip的地址切换,双机热备功能的实现。
LVS+Keepalived双机热备的实现步骤大致如下: 1. **配置LVS**:首先,在两台服务器上分别安装LVS,设置相应的负载均衡策略,例如轮询、权重分配等。然后,配置虚拟IP地址,这将是对外提供服务的统一入口。 2. **...
在这个场景中,keepalived和nginx结合使用,可以实现Web服务的双机热备和负载均衡。 **虚拟IP切换** 在Keepalived的配置中,通常会设置一个虚拟IP地址(VIP),这个地址对外公开,用户访问的是这个IP,而不是具体...
redhat6.4+nginx+keepalived__实现双机热备和负载均衡
在实际生产环境中,为了提高Web服务的可用性和稳定性,通常会采用双机热备方案来实现服务的高可用性(High Availability, HA)。本实验通过使用Keepalived软件,在Linux环境下构建一个Web服务器的双机热备系统,旨在...
【Nginx+Keepalived实现双机热备】 在高可用性系统设计中,双机热备是一种常见的策略,可以确保服务在一台服务器故障时能够无缝切换到另一台服务器,从而保持系统的不间断运行。Nginx是一款高性能的HTTP和反向代理...
2. 热备实现技术: - Heartbeat:一种开源的监控和故障转移工具,用于检测服务器状态并进行切换。 - VCS(Virtual Cluster System):提供集群管理,支持多种热备策略。 - Keepalived:常用于Linux环境,结合...